Nexeed
    • Introduction
    • User manual
      • General descriptions
        • Result lists
        • Scope Concept
      • Basic setup
        • Connection management
        • Scope Management
          • Configuration Scopes
          • Reporting Scopes
      • Traceability
        • Types of evaluations
        • Search Forms for creating an evaluation
        • Part Protocol
          • Quick Search
          • Extended Search
          • Part View
          • Process View
          • Component View
          • Part Information
          • Process Information
        • Forward Search
          • Quick Search
          • Extended Search
        • Backward Search
        • Tool Usage
        • Packaging Information
          • Quick Search
          • Extended Search
      • Archiving
        • Enable archiving
        • Monitoring
      • Quality Gate
        • Types of Quality Gate Checks
        • Working with Test Specifications
        • Testing of Test Specifications
          • Basic test client
          • Expert test client
          • JSON based test client
      • Terms and definitions
        • Archiving states
        • Connection states
        • Packaging data
        • Part blocks
        • Process data
        • SPC session data
        • Test Specifications
    • Operations manual
      • Overview
      • System architecture and interfaces
        • Data Collector Service
        • Data Browser Service
        • Archiving Bridge Adapter Service
        • Configuration Service
        • Quality Gate Service
        • Reporting Service
        • Quality Database (QDB)
        • Archiving Bridge Adapter Service database
      • System requirements
      • Migration from previous versions
        • Migration from MES QualityData
        • Part Traceability upgrades
      • Setup and configuration
        • Base configuration
        • Quick start configuration
        • Application and service account roles
        • Scope-based configurations
        • Data Collector Service
        • Data Browser Service
        • Archiving Bridge Adapter Service
        • Reporting Service
        • Quality Database (QDB)
        • Module database
        • Archiving Bridge Adapter Service database (QDAB)
        • Resources in Part Traceability
        • Dos and don’ts in databases
      • Start and shutdown
      • Regular operations
      • Failure handling
      • Backup and restore
      • Logging and monitoring
      • Known limitations
    • Developer documentation
      • Deep Dives
        • Forwarding via Data Publisher
        • Resolving of Scopes
      • Quality Gate Checks
        • Structuring of Test Specifications
        • Input and output parameters
          • Check Block List
          • Check Complete (location based)
          • Check Complete (process based)
          • Check Component
          • Bypass Check Complete
          • Check Trace Mapping
          • Check Characteristics
      • Troubleshooting
    • API documentation
      • Data Browser Service
      • Data Collector Service
        • Structure and content of telegrams
          • basicInfo
          • partDetails
          • componentTrace
          • additionalInfo
          • packaging
      • Quality Gate Service
      • Archiving Bridge Adapter Service
    • Glossary
Part Traceability
  • Industrial Application System
  • Core Services
    • Block Management
    • Deviation Processor
    • ID Builder
    • Multitenant Access Control
    • Notification Service
    • Ticket Management
    • Web Portal
  • Shopfloor Management
    • Andon Live
    • Global Production Overview
    • KPI Reporting
    • Operational Routines
    • Shift Book
    • Shopfloor Management Administration
  • Product & Quality
    • Product Setup Management
    • Part Traceability
    • Process Quality
    • Setup Specs
  • Execution
    • Line Control
    • Material Management
    • Order Management
    • Packaging Control
    • Rework Control
  • Intralogistics
    • AGV Control Center
    • Stock Management
    • Transport Management
  • Machine & Equipment
    • Condition Monitoring
    • Device Portal
    • Maintenance Management
    • Tool Management
  • Enterprise & Shopfloor Integration
    • Archiving Bridge
    • Data Publisher
    • Engineering UI
    • ERP Connectivity
    • Gateway
    • Information Router
    • Master Data Management
    • Orchestrator

Nexeed Learning Portal

  • Part Traceability
  • User manual
  • Archiving
  • Enable archiving

Enable archiving

Data collected prior to enabling archiving cannot be included in the archiving process retrospectively.

Prerequisites

  • Archiving Bridge module is installed and configured.

  • ArchivingBridge Config Reader role is assigned to Part Traceability module.

Procedure

  1. Open Part Traceability > Configuration menu entry.

  2. Click on the Scope Management tab.

  3. Click on the Configuration Scope to be edited.

    A side panel opens. The General tab is shown.

  4. Click on the Settings tab.

    Scope Management Settings

  5. Toggle on the Enable Archiving switch Enable Archive.

    The switch turns blue and archiving is enabled, but needs additional configuration.

  6. Click on edit_blue_button.

    The dialog window opens.

  7. Click on the Archive that shall be assigned to the Configuration Scope.

  8. Click on Apply.

    The dialog window is closed and the Archive is shown in the Settings tab.

    Saved Archiving Settings
  9. Click on Save.

    The archiving process is enabled.

Contents

© Robert Bosch Manufacturing Solutions GmbH 2023-2025, all rights reserved

Changelog Corporate information Legal notice Data protection notice Third party licenses