Ending the Process (Reject)
The rejection dialog is only displayed in the event of the two-stage packaging step, that is, a pallet which contains boxes into which the individual parts were packed.
For a single-stage packaging step, i.e. a box or pallet, which is filled with parts, this dialog is not active, because it is obvious which packaging unit should be rejected.

-
Select Pallet incl. boxes (reject all) in the rejection dialog.
The pallet with all assigned boxes and products is deleted together with the packaging information.
or
-
Select Pallet only (keep boxes) in the rejection dialog.
Only the boxes from the pallet will be unpacked and remain in the memory for repacking.
The respective specifications, depending on the configuration or calculations can be found in the section Specifications for rejection dialog.
Specifications for rejection dialog
-
LocationParameter "AllowedPalletRejectionUseCases" in the service configuration: "Pallet only (keep boxes)"
-
LocationParameter "AllowedPalletRejectionUseCases" in the service configuration: "Pallet incl. boxes (reject all) or “Pallet only (keep boxes)"
-
User does not have "Execute" rights for the AccessControl Resource "AbortDialogRejectAllOption”
-
User has "Execute” rights for the AccessControl Resource "AbortDialogRejectAllOption" or after login by a user having "Execute" rights
-
-
LocationParameter "AllowedPalletRejectionUseCases" in the service configuration: "Pallet incl. boxes (reject all)"
-
User does not have "Execute" rights for the AccessControl Resource "AbortDialogRejectAllOption”
-
User has "Execute” rights for the AccessControl Resource "AbortDialogRejectAllOption" or after login by a user having "Execute" rights
-
Confirmation dialog for rejection
If a packaging unit should be discarded, the user confirms the action through a dialog prior to running the reject process.
The dialog is activated/deactivated through the following configuration methods:
-
DisplayConfirmationDialogBeforeAbortPackage Client LocationParameter in the serv ice configuration
-
SkipConfirmationDialogs AccessControl Resource
The confirmation dialog is displayed if the active user does not have "Execute" rights for SkipConfirmationDialogs and the parameter DisplayConfirmationDialogBeforeAbortPackage is set to "true."
-
Display when rejecting a two-stage pallet via the option "Pallet incl. boxes (reject all)"
-
Display when rejecting a two-stage pallet via the option "Pallet incl. boxes (reject all)”
-
Display when rejecting a single stage pallet
-
Display when rejecting a box