Diese Seite ist nur auf Englisch verfügbar.

Known limitations

Performance efficiency - time behaviour

Condition Monitoring can handle 50 concurrent users per tenant. (50 logged in/parallel working users)

CM must be able to persist permanently 600 PPMP/OPP messages per 1 second on a single tenant via http without loosing a message and responding within 1 second.

  • 400 machine messages

  • 200 measurement message (20000 measurements/second)

  • max. 5.000 rules (in average one rule per device for a large customer)

  • average 2 rules for a single measurement

  • Rule result need to be available within 3 seconds

  • For all incoming messages the Rule Service App must ensure that they are processed before they are removed from the input topic by its configured retention policy.

  • Per tenant the Rule Service App must be able to process all applicable rules and publish the rule result in average in less than 3 seconds after arrival.

Rest API
must respond within

  • max. 3 seconds (peak load)

  • average 0,5 seconds

  • CM displays an incoming measurement message to the user within 3 seconds when the live measurement chart is opened.

  • CM displays the live measurement chart within 2 seconds (maximum 1000 values) at the first call.

CM displays historical data within 2 seconds for the following parameters:

  1. Raw data:

    • Timerange: 5 min

    • Interval: raw

    • 5 device properties

  2. Level 1 (1 minute aggregation):

    • Timerange: 6 hours

    • Interval: 1 minute

    • Aggregation types: median, min, max

    • 3 device properties

  3. Level 2 (30 minute aggregation):

    • Timerange: 7 days

    • Interval: 1 hour

    • Aggregation types: median, min, max, median, count

    • 3 device properties

Performance efficiency - capacity (storage time, data volume)

  • CM can show 7 days of raw measurement data (or a dataset that looks like 7 days of raw data) in the UI in order to serve visual analysis use cases.

Performance efficiency - capacity (message size)

The maximum message size CM supports with the given quantity structure:

  • PPMP/OPP Machine Message: 1 kB

  • PPMP/OPP Measurement Message: 5kB

Performance efficiency - time behavior (eps)

Measurements Export

  • Raw, CSV: The Export service is able to export 6 hours of raw measurements with 4 measurement points (200 measurements/sec = 2.160.000 measurements) into a downloadable csv-file within 12 minutes constant with 30 seconds pause in between.

  • 1 minutes aggregation, CSV: The Export service is able to export 3 days of aggregated measurements with 4 measurement points (100 measurements/sec = 432.000 measurements) into a downloadable csv-file within 12 minutes with 1 hour pause in between.

Edit this pageDiese Seite bearbeiten