Nexeed
    • Introduction
    • User manual
      • Condition monitoring and its tabs
        • Live
        • Counters
        • Measurements
        • Events
        • Rules
        • View configuration
        • Details
      • Rules management
        • Rule types and standard functions
        • Rule details
      • Function configuration
      • Condition Monitoring widgets
      • Access Management
        • Application Roles
        • Fine-Grained Access Control and Configuration
        • How to Configure Organization Roles
    • Operations manual
      • Overview
      • System architecture and interfaces
        • System components
      • System requirements
        • General notes
        • cm/condition-monitoring-core
        • cm/rule-service-app
        • cm/rule-function-executor
        • cm/rule-result-aggregator
        • cm/rule-value-aggregator
        • cm/rule-value-provider
        • cm/stateful-function-executor
      • Migration from previous versions
        • Migration to 2.1+
        • Migration from CPM 1.5.4 to CM and RM 3.0.x (Nexeed IAS 2023.02.00.xx)
          • CPM to CM relational database migration
          • CPM to RM relational database migration
          • CM Influx database migration
          • Deletion of an old CPM installation
        • Resources mapping from MES to IAS Condition Monitoring
        • Migration to 4.0.0+ (Nexeed IAS 2024.01.00.xx)
        • Migration to 4.3.x (Nexeed IAS 2024.02.01.x)
        • Migration to 4.5.x (Nexeed IAS 2025.01.00.x)
        • Migration to 4.6.x (Nexeed IAS 2025.01.01.x)
        • Migration to 4.8.x (Nexeed IAS 2025.02.00.x)
        • Migration to 4.9.x (Nexeed IAS 2025.02.01.x)
      • Setup and configuration
        • Manual MACMA configuration after setting up a new tenant
        • RabbitMQ
        • Influx configuration
        • Kafka topics
        • Condition Monitoring - Helm Configuration
        • Advanced configuration parameters
          • cm/condition-monitoring-core
            • Common shared variables
            • Portal shared variables
            • MDM shared variables
            • RabbitMQ shared variables
            • OTEL shared variables
          • cm/rule-service-app
            • Rules Management shared variables
            • KAFKA shared variables
          • cm/rule-function-executor
          • cm/rule-result-aggregator
          • cm/rule-value-aggregator
          • cm/rule-value-provider
          • cm/stateful-function-executor
      • Start and shutdown
      • Regular operations
      • Failure handling
        • Rule Management Light Helm installation failing when Kafka is disabled or Kafka is not configured at all
        • User manual injection into Rule Management
        • Infrastructure outages: health verification Endpoints
        • OPP/PPMP are not received in CM
        • Master data (Devices, Facilities, Measuring Points, DeviceTypes) is missing in CM
        • CM is not visible in the portal
        • How to verify if the broker is out of sync
      • Backup and Restore
      • Logging and monitoring
        • General logging characteristics
        • Required monitoring
        • General logging format
        • Request-based logging format
        • Security logging format
        • Lifecycle logging format
        • Module health Endpoints and K8s probes
      • Known limitations
    • API documentation
      • Condition Monitoring HTTP API
      • Rules Management HTTP API
    • Glossary
Condition Monitoring
  • Industrial Application System
  • Core Services
    • Block Management
    • Deviation Processor
    • ID Builder
    • Multitenant Access Control
    • Notification Service
    • Ticket Management
    • Web Portal
  • Shopfloor Management
    • Andon Live
    • Global Production Overview
    • KPI Reporting
    • Operational Routines
    • Shift Book
    • Shopfloor Management Administration
  • Product & Quality
    • Product Setup Management
    • Part Traceability
    • Process Quality
    • Setup Specs
  • Execution
    • Line Control
    • Material Management
    • Order Management
    • Packaging Control
    • Rework Control
  • Intralogistics
    • AGV Control Center
    • Stock Management
    • Transport Management
  • Machine & Equipment
    • Condition Monitoring
    • Device Portal
    • Maintenance Management
    • Tool Management
  • Enterprise & Shopfloor Integration
    • Archiving Bridge
    • Data Publisher
    • Direct Data Link
    • Engineering UI
    • ERP Connectivity
    • Gateway
    • Information Router
    • Master Data Management
    • Orchestrator

Nexeed Learning Portal

  • Condition Monitoring
  • User manual
  • Rules management
preview 4.10.0

Rules management

The Rules management menu is used to manage rules globally.

  • To define a new rule for a device or for a device type that creates an event in addition to machine messages sent by the machine itself

  • To define preconditions when a rule can be executed

  • To define reactions a rule has to trigger when the rule condition is met

  • To edit, copy and delete rules

  • To activate/deactivate rules

Rules Light and Rules Extended has here different capabilities. Rules Extended has a greater range of functions than Rules Light :
Introduction to the Condition Monitoring module

Overview

In this view, all rules are listed and can be managed. New rules can be created, updated, copied or deleted. It is also possible to change the state of a rule to Active, Inactive or Waiting for Approval. Within the overview it is possible to jump to rule related views, like creating a quick reaction in Deviation Management Module.

cm_rm_overview_2023_01
Element Description

Facilities

Select facilities to filter the list of rules.

XX items

Number of rules in the overview.

Code, title search

Search rule with Code or Title

filter Filter

Filter the overview by selecting State , Severity , Context, Part Type and Conditions in the dialog window.

tune View

Show or hide columns in the overview.

filter-success

Save the current filter settings for the logged-in user.

add_border

Create or Configure a Rule

Column title

Sort the overview by clicking on the column title.

settings-editor

Context menu with the following options: Change state, Show History, Copy Rule and Delete Rule.

fullscreen

Context menu with where modules can place possible actions based on the rule, like creating a quick reaction in Deviation Management Module.

Create a new rule

To create a new rule, click add_border in the overview page.

cm_rm_create_rule

Fill the mandatory fields (marked with an asterisk *). Select if the rule should be created for a specific device or for a device type. Depending on this selection *Device* or Device Type need to selected as next step.

If a rule is created out of Performance analysis, the device is already preselected and cannot be changed.

After click on save, the new rule is created and the detail view of the rule opens, where further configurations can be done. See: Rule details page